Converting Your Inverter to Floating Neutral (201407)
The following bulletin covers the following models: 201407.
Please read and view the following instructions carefully and completely before performing the service.
SAFETY PRECAUTIONS
- To reduce the risk of injury, user must read and understand the operator’s manual before using this product.
- DO NOT make any adjustments to the generator without first stopping the engine and disconnecting the spark plug wire.
- Burns from hot parts — let the engine cool completely before touching hot parts.
- Injury from moving parts.
- To reduce the possibility of fire or explosion, be careful when working around gasoline. Keep cigarettes, sparks and flames away from all fuel‐related parts.
- Remove the eight bolts from the main panel.
- Locate the neutral and ground wrire bonding point, which is circled in red.
- Use an 8 mm socket to remove the "N" wire.
- Cover the end of the neutral wire with electrical tape.
- Put the service panel back on.